WG Calibration - CLKB1 Kits Series
Sliding Load Calibration, Short-Short-Load-Through (SSLT) calibration method using offset short
Features
1.7 to 40GHz
WR430 Through WR28
Short-Short-Load-Through (SSLT) calibration method using offset short
Sliding Load Calibration
Keysight (Agilent), Anritsu and Rohde & Schwarz VNAs Supported
Description
The A-INFO CLKB1 Series Calibration Kits are waveguide kits designed to provide accurate SSLT(Short-Short-Load-Thru) calibration of VNA for measurement in rectangular waveguide from WR430 to WR28 (1.7 to 40GHz). CLKB1 Series Calibration Kits provide all the necessary components for an accurate SSLT calibration. In addition to SSLT calibration, CLKB1 Series can also make one-port SSL(Short-Short-Load) calibration. All kit components have both standard flange and precision flange(APF Series).
Components included in CLKB1 Series Waveguide Calibration Kits
QTY
|
Description
|
Notes
|
2
|
WG to Coaxial Adapter
|
Refer below table for each WG band.
|
1
|
Precision Fixed termination
|
-
|
1
|
Precision Sliding termination
|
-
|
1
|
Fixed (reference plane) Short
|
-
|
1
|
1/8λ high precision offset short
|
-
|
1
|
3/8λ high precision offset short
|
-
|
1
|
Verification Standard
|
-
|
1~3
|
Screw Pack
|
Qty is depending on WG band. |
1
|
Dowel Pack*
|
For APF flange only.
|
1
|
Hex Ball Driver
|
-
|
1
|
Calibration Software** |
- |
1
|
Carrying Case
|
-
|
Notes:
*Indexing refer Precision Flange (APF)
**Calibration Software currently supports Keysight 872x Series, PNA Series, Anritsu and Rohde&Schwarz ZVx Series . Please ask A-INFO for more information when place order.
|